For each FLUXI 2000 TZ and DELTA meters, correction according to pressure, temperature and compressibility factor (meaning the transformation in real volume of consumed gas) is made with the gas volume converter CORUS (PTZ).
Corector electronic de volum de gaz tip CORUS (PTZ)
Gas volume converter CORUS (PTZ)
General Technical Data
- Pressure measurement range : 0,9 – 80 bar
- Maximum measurement error :
- For pressure sensor : ±0,3%
- For temperature sensor : ±0,1%
- For correction coefficient : ±0,3% (la 20oC)
- Operation conditions :
- Environment temperature : -25 to +55oC
- Gas temperature : -40 to +70oC
- Internal battery autonomy : 5 years
- Pressure transducer : PTZ
- Temperature transducer : PT 1000 (class A, 4 wires)
- Correction coefficient calculation according to : AGANX19, AGANX19 amended, S-CERG, AGA8, Table Z
- Cable connexions type : F 4114-60
- Data storage period : 8 years
- Lifetime : minimum 16 years.